Leave comments or report a bug

Simply leave your comments below. If the feedback is about a bug, please provide the steps you took so we can replicate.

Upload files

You can use CTR+V to paste a screenshot from your clipboard directly into the textarea above. Otherwise you can upload a file from your computer below.

Select a theme

These themes change the colour scheme and fonts of this site to make it easier to read.

If there are ways that we can make the site more accessible to you, please contact us.

back to top

It disposes or re-uses the wastewater generated within the property. This water must remain within the property boundary. There are a few simple measures that can be undertaken to ensure that your LAA is working effectively.

Trenches

Trench based systems utilise primary treated wastewater that has not been chlorinated. The water will contain high levels of bacteria and potential pathogenic organisms. To avoid human and animal contact, the wastewater disposal happens below the soil surface.

Reasons for these systems to fail include:

  • solids from the septic tank or primary chamber carry over to the trenches and block the pores of the soil. This can prevent the effluent from being absorbed into the soil and cause the trenches to overflow
  • tree roots block pipes and trenches
  • overgrown LAAs prevent sun and wind from transpiring excess moisture
  • out of level trenches not working to full capacity due to soil settlement. This can result in trenches overflowing at any low point.

Surface irrigation

Surface irrigation systems distribute secondary quality chlorinated effluent over grassed or gardened LAAs to re-use the wastewater.

Reasons for these systems to fail include:

  • failing treatment plant resulting in poor water quality
  • sprinklers not being moved or rotated
  • no chlorine in the system
  • sprinklers too close to neighbouring properties
  • blocked filter, if fitted
  • poor drainage in the top layer of soil resulting in ponding in the LAA.

Sub surface irrigation

Sub surface irrigation systems distribute secondary quality chlorinated effluent to the LAA via a network of small bore piping. The piping has drippers spaced regularly to spread the effluent over the LAA.

Reasons for these systems to fail include:

  • small particles flowing from the treatment plant can block the drippers in the small bore pipework
  • blocked or damaged indexing valve can cause incorrect dosing to the LAA
  • blocked filter
  • poor drainage in the top layer of soil resulting in ponding in the LAA.

Plants to assist in your land application area

Choose shallow-rooted plants and grass or groundcovers and climbers for your land application area. Keep grass regularly mowed and plant small trees around the perimeter to aid absorption and transpiration of the treated wastewater. Plant downstream of the absorption/transpiration trenches. Some water-loving plants, trees, and shrubs can quickly overgrow. Roots will clog the system and invade the pipes.

Refer to our recommended vegetation to assist land application areas fact sheet.